48
DT330 Compatibility Settings
Terminal Lot Number DT-330
ADA-L Unit Switch
Settings
xxx I Lx or lower xxx I Mx xxxJSx or higher
(Version 1.E0 or lower) (Version 8.10) (Version 2.20 or higher)
ADA Connection for
Recording Only.
Dip switches 1, 2, 3, 5, 7
and 8 are OFF. Switches
4 and 6 are ON.
Dip switches 1, 2, 3, 5, 7
and 8 are OFF. Switches
4 and 6 are ON.
Dip switches 1, 2, 3, 5, 7
and 8 are OFF. Switches 4
and 6 are ON.
ADA Connection for
Sending Recorded Calls
to the Telephone.
Dip switches 2, 3, 5, 7 and
8 are OFF. Switches 1, 4
and 6 are ON.
Dip switches 2, 3, 5, 7 and
8 are OFF. Switches 1, 4
and 6 are ON.
Dip switches 2, 3, 5, 7 and
8 are OFF. Switches 1, 4
and 6 are ON.
To Send and Receive to
the Terminal
Not supported
Dip switches 1, 2, 3, 5, 7
and 8 are OFF. Switches
4 and 6 are ON.
Dip switches 1, 2, 3, 5, 7
and 8 are OFF. Switches 4
and 6 are ON.
Lot Numbers: I, J Hardware Revision
Lot Numbers: L, M, S Software Revision
To verify DT-330 terminal firmware, hold down keypad buttons 1, 2 and 3 while plugging the line cord into the
terminal.
Firmware Compatibility Matrix
BCH-L Unit Lot Number
xxxDxx or lower xxxExx or higher
Terminal Lot Number
DT-330
xxx I xx or lower
(Version 8.10 and 1, E0 or lower)
Supported
Supported
xxxJxx or higher
(Version 2.20 or higher)
Not supported
Supported
BCH Support may differ based on terminal firmware. To verify both DT-330 terminal and BCH-L Unit firmware,
hold down keypad buttons 1, 2 and 3 while plugging the line cord into the terminal.