50
Program
Number
Program Name/Description
Input Data
Default
15-03-01
Single Line Telephone Basic Data Setup
SLT Signaling Type
Select the type of dialing the connected
telephone uses.
For the UNIVERGE SV9100 Wireless
telephones to function correctly, this must be
set to 0. If this option is set for DTMF, after an
outside call is placed, the system cannot dial
any additional digit.
This program change is automatically
performed when the UNIVERGE SV9100
Wireless telephone is registered. When
upgrading software from prior versions, the
previous default of 1 is saved from the prior
database so this option must be changed
manually.
0 = DP
1 = DTMF
1
15-03-04
Single Line Telephone Basic Data Setup
Flashing
Enable/Disable Flash for single line (500/2500
type) telephones.
0 = No
1 = Yes
1
Operation
Depends on the connected ancillary device.