Service Tone Setup Defaults, Program 80-01-01 (Continued)
Service
Tone No.
Service Tone
Repeat
Count
Unit
Count
Basic
Tone No.
Duration
Gain Level
(dB)
4
Internal Recall Dial Tone
2
Basic 2
9
1
32 (0dB)
0
1
32 (0dB)
5
Trunk Dial Tone
0
Basic 1
9
10
32 (0dB)
6
Internal Busy Tone
0
Basic 2
0
5
20 (-6dB)
11
5
20 (-6dB)
7
DND Busy Tone
0
Basic 2
0
2
32 (0dB)
1
2
32 (0dB)
8
B-Busy Tone
0
Basic 2
0
5
20 (-6dB)
11
5
20 (-6dB)
9
Internal Reorder Tone
0
Basic 2
11
3
20 (-6dB)
0
2
20 (-6dB)
10
Internal Interrupt Tone
0
Basic 2
0
1
32 (0dB)
1
1
32 (0dB)
11
Internal Confirmation Tone
3
Basic 2
0
5
32 (0dB)
6
1
32 (0dB)
12
Internal Hold Tone
0
Basic 0
0
0
32 (0dB)
13
External Hold Tone
0
Basic 0
0
0
32 (0dB)
14
Intercom Ringback Tone
0
Basic 2
9
10
32 (0dB)
0
20
32 (0dB)
15
Override Tone
1
Basic 1
12
5
32 (0dB)
16
Lock-Out Tone
0
Basic 2
0
1
32 (0dB)
6
1
32 (0dB)
17
Clock Alarm Tone
0
Basic 4
6
1
32 (0dB)
0
1
32 (0dB)
6
1
32 (0dB)
0
7
32 (0dB)
18
BGM
0
Basic 0
0
0
32 (0dB)
19
Door Box Chime 1
3
Basic 6
4
2
38 (+3dB)
4
2
26 (-3dB)
2
3
38 (+3dB)
2
4
26 (-3dB)
2
6
14 (-9dB)
0
5
32 (0dB)
20
Door Box Chime 2
3
Basic 6
7
2
38 (+3dB)
7
2
26 (-3dB)
5
3
38 (+3dB)
5
4
26 (-3dB)
5
6
14 (-9dB)
0
5
32 (0dB)
21
Door Box Chime 3
3
Basic 6
8
2
38 (+3dB)
8
2
26 (-3dB)
6
3
38 (+3dB)
6
4
26 (-3dB)
6
6
14 (-9dB)
0
5
32 (0dB)