Program
Number
Program Name/Description
Input Data
Default
80-03-03
DTMF Tone Receiver Setup Min. Detect
Level
For the extension DTMF, the minimum Detect
Level (0-15) for the DTMF Tone must be set to
allow a minimum detection level of -25dBm.
This entry is dependent on the Detect Level
selected in Program 80-03-01. For example, if
Detect Level 0 were selected in Program
80-03-01, the entry in this option would be 15
for -25dBm. The system must be reset for this
change to take affect.
0 ~ 15
detect level 0:
-10dBm(0) to -25dBm(15)
detect level 1:
-15dBm(0) to -30dBm(15)
detect level 2:
-20dBm(0) to -35dBm(15)
detect level 3:
-25dBm(0) to -40dBm(15)
detect level 4:
-30dBm(0) to -45dBm(15)
detect level 5:
-35dBm(0) to -50dBm(15)
detect level 6:
-40dBm(0) to -55dBm(15)
detect level 7:
-45dBm(0) to -60dBm(15)
detect level 8:
-50dBm(0) to -65dBm(15)
detect level 9:
-55dBm(0) to -70dBm(15)
detect level 10:
-60dBm(0) to -75dBm(15)
detect level 11:
-65dBm(0) to -80dBm(15)
detect level 12:
-70dBm(0) to -85dBm(15)
detect level 13:
-75dBm(0) to -90dBm(15)
detect level 14:
-80dBm(0) to -95dBm(15)
detect level 15:
-85dBm(0) to -100dBm(15)