939
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
20-01-01
System Options Operator Access Mode
Set up priority of a call when calling an operator
telephone (0 = Step, 1 = Circular).
0 = Step
1 = Circular
0
20-17-01
Operator Extension Operator’s Extension
Number
Designate an extension an operator. When an
extension user dials 0 or 9 (defined by Program
11-01, Type 5), calls go to the operator selected
in this program.
If you do not assign an extension in Program
90-11-01, system alarms appear on the
extension assigned in this option.
Maximum of eight digits.
200
20-35-01
Extension’s Operator Setting
Assign an extension to an operator group.
0 ~ 15
0
20-36-01
Trunk’s Operator Setting
Allow the user to select Operator Group per
trunk.
0 ~ 15
(0 = Not assigned)
0
20-37-01
Operator Extension Group Setup
Define the initial operator extension in the
operator group.
0 ~ 9,
*
, # Maximum of eight
digits
No Setting
20-38-01
Operator Group Setting Operator Access
Mode
Set up priority of a call when calling an operator
telephone.
0 = Step
1 = Circular
0
Operation
Refer to the individual features for operation.

Table of Contents