UNIVERGE SV9100 Issue 1.2
System Hardware Manual 4 - 33
ADP adapters)
These ports provide -48V feeding.
Two blade status LEDs – One Live LED, One Busy/Idle LED
Table 4-13 GCD-8DLCA/GCD-16DLCA Maximum Upgrade
Capacities provides the maximum capacities for the ESIU blades
when they are upgraded.
4.1.2 Installation
The GCD-8DLCA/GCD-16DLCA blades can be installed in any
universal slot in the system and up to a maximum of 20 DLCA blades
can be installed per system, providing up to 368 digital ports.
To install the GPZ-8DLCB
/GCD-16DLCA:
1. If installing the GCD-8DLCA and the GPZ-8DLCB daughter
board is to be attached, do so now. Refer to 4.2.2 Installation
on page 4-38.
2. Each CNx01 connector (CN101, CN201, CN301, CN401) is
used to connect up to four digital extensions.
4.1.3 LED Indications
LEDs for the GCD-8DLCA
/GCD-16DLCA are described in Table 4-
14 GCD-8DLCA/GCD-16DLCA LED Indications. Each LED is listed
with its associated function and LED and Operational status. Refer
to Figure 4-9 GCD-8DLCA/GCD-16DLCA/ Blade and for the
location of the LEDs on the blades.
Table 4-13 GCD-8DLCA/GCD-16DLCA Maximum Upgrade Capacities
ESIU
19”
Chassis
with CPU
19” Chassis
without CPU
19” Chassis
x4
Networked
Chassis
GCD-8DLCA
56 2332
GCD-16DLCA
55 2032
Table 4-14 GCD-8DLCA/GCD-16DLCA LED Indications
LED Indication
Operation Status Remarks
Live LED
(Green)
Busy LED
(Red)
On On System Initializing –