9
C2
Check DC voltages with a
meter and AC power with a
line disturbance analyser
Increase Automatic Release
Signal
Detection Time. Refer to
PRG 14-02-09.
Perform First Initialization.
Replace GCD-CP10, and test
system using default
program.
Have Telco check
Line
circuit(s).
Return Defective blade
for
repair.
See if problem exists
on all
Lines.
Check outside line key
after
call drops.
Check GCD-4COTA LED.
1.
Perform Second Initialization.
If trouble persists
go to step 2.
2.
Replace GCD-4COTA. Test.
Call Dropping
No
Calls
dropped on
all lines?
Yes
No
All
lines at same
time?
Yes
Line Key
LED Status?
Off
GCD-4COTA
LED Status?
On
No
Problem
Solved?
Yes