UNIVERGE SV9100
Issue 1.0
System Maintenance Manual
11
Program as DP.
1.
Reset GCD-4COTA. If trouble persists,
go to next step.
2.
Replace GCD-CP10, and test.
3.
Perform Second Initialization, and test.
4.
Perform First Initialization, and test.
5.
Replace GCD-CP10.
Check CO lines at MDF with test
set to see if they
are DTMF or
DP.
Check
PRG 15-03-01.
Check CO lines at MDF with test
set to see if they
are DTMF or
DP.
Check CO lines at MDF with test
set to see if they
are DTMF or
DP.
Check PRG 14-01-10
Selection to ensure lines are
programmed for DP.
Program lines for DTMF.
Program lines for DP.
Monitor Line with test set, and
verify if system
is sending digits.
CO/PBX Dialing Problem: Cannot Dial Out on CO
No
SLT
problem
only?
DTMF
DTMF
DP
DP or
DTMF?
Line type
program?
DP
DTMF
DP
DP or
DTMF?
DP
DP or
DTMF?
Programmed
for?
DP
DTMF
DTMF
Yes
No
Digits Sent?
C4
1.
If lines are DTMF, increase the DTMF
duration in
PRG 80-02-01.
2.
If lines are DP, choose 10 or 20 pps
option in
PRG 14-02-01.
3.
Check off-hook CO line current.