Issue 1.0
UNIVERGE SV9100
12
System Maintenance
Go to Flowchart A2.
Send terminal
in for
repair.
Replace station cable.
Check PRG 10-03-01for
correct
Station Assignment.
Reassign.
Perform Multiline Terminal Self Test:
1.
Unplug terminal line cord.
2.
Hold down * and # together and plug in the line cord.
3.
Press each terminal key to test tones, LEDs, and key contacts.
4.
Return terminal on-line by taking handset off-hook and then
return to on-
hook.
Reset and test. Replace defective
terminal, and
test.
Connect terminal directly
to
MDF, and test.
Reset and test. Replace
faulty GCD-
8DLCA.
Multiline Terminal Function Problems
Yes
All
terminals?
No
No
Assignment
correct?
Yes
Yes
Problem
solved?
No
Yes
No
Problem
solved?
No
Problem
solved?
Yes
D1
1. Perform Second Initilization and test
2. Perform First Initialization and test
3. Replace GCD-CP10 and test using default program
Problem
Solved?
Send GCD-8DLCA in for repair
No
Yes