72
Issue 1.0
UNIVERGE SV9100
System Maintenance Manual
Alarm
No.
Type
Name
Content of Alarm
Cause
Action
Recovery
13
Not set
Charge
Management
Link Error
The link with the charge
management device
came off.
1. Problem of wiring to
connect main device with
charge management device.
Minor. Problem of PC.
1. It is confirmed that
there is no problem in
wiring to connect a
main device with the
charge management
device. (Whether ping
passes for LAN
connection is
confirmed.)
Minor. Restart the
charge management
software. 3. Reboot
PC, and start the
charge management
software.
When the
connection returns
normally, the error
is recover.
14
Not set
LAN Link Error
The link with LAN on CD-
CP00 came off.
• LAN cable defective.
• Connected HUB broken.
• Defect of CD-CP00
Confirm the operation
of LAN connector, LAN
cable, and HUB again.
When the
connection returns
normally, the error
is recover.
15
Not set
Network Keep
Alive
1. The network
connection has been
cut. Minor. Network
Keep Alive restoration.3.
Response notification on
network Keep Alive.
• LAN cable is defective.
• Net side trouble.
• Packet block by firewall.
• Repetition of IP address.
Confirm whether the
defect is on the
Network side. Confirm
the settings of HUB
and the router, etc.
When the
connection returns
normally, the error
is recovered.
16
Not set
SMDR Link
17~18
Not set
--- Reserved ---
19
Not set
Charge
Management
Buffer full
The temporary buffer
for the charge
management in main
device was overflowed,
and a part of unoutput
charge data disappeared
because it was not able
to output the charge
management data.
1. The charge data is printed
and not deleted at the
simple charge management.
Minor. The charge data is
not output to PC for the
charge management
software.
1. Please print and
delete the charge data
at the simple charge
management.
Minor. Please connect
the charge
management software
for the charge
management software
and output the charge
data.
When the output
is restarted, the
error is recovered.
However, the
charge
management data
after the error
occurs is not
recorded.
30
Minor
SMDR Buffer full
The temporary buffer
for SMDR in main device
was overflowed, and a
part of unoutput SMDR
data disappeared
because it was not able
to output SMDR data.
1. Problem of wiring to
connect main device with
PC.
Minor. Problem of PC.
1. Please confirm
whether there is
problem in wiring to
connect a main device
with PC.
Minor. Please execute
the reactivation of PC.
When the output
is restarted, the
error is recovered.
However, the
SMDR data after
the error occurs is
not recorded.
31~34
Not set
--- Reserved ---