UNIVERGE SV9100
System Maintenance Manual
Alarm
No.
Type
Name
Content of Alarm
Cause
Action
Recovery
38
Not set
CSIU Dch Error×
It was restored
automatically specifying
reset to concerned CS
with a main device
because a main device
had detected the control
signal from a main
device not normally
reaching CS.
1. Outgoing noise.
Minor. Method of setting up
CS.
3. Wiring to connect CSIU
unit with CS.
4. Hard defect of CS.
5. Hard defect of CSIU.
Please confirm the
following matter when
happening frequently
when operating it.
1. Please confirm CS is
normally connected.
Minor. Please confirm
the wiring between
CSIU-CS is normal.
3. Please exchange CS.
4. Please exchange
CSIU.
This error has
been recovered
when it is notified.
39
Not set
CSIU
transmission
error.
This alarm is integrated
into "Communication
fault between the CD-
CP00 and other PKG",
and it is not used in
SV9100.
40
Not set
CS error
notification
Minor.
CS detected the factor
that the noise is
generated between CS-
PS, BBIC reset was
executed, and it was
restored automatically.
1. Outgoing noise.
Minor. Method of setting up
CS.
3. Wiring to connect CSIU
unit with CS.
4. Hard defect of CS.
5. Hard defect of CSIU.
Please confirm the
following matter when
happening frequently
when operating it.
1. Please confirm CS is
normally connected.
Minor. Please confirm
the wiring between
CSIU-CS is normal.
3. Please exchange CS.
4. Please exchange
CSIU.
This error has
been recovered
when it is notified.
41~49
Not set
--- Reserved ---
50
Major
System Start
Notification
The system started.
The system was started.
No action needed.
51
Not set
System Data
change
CD-CP00 Upgrade is
performed or
Programming change is
made.
No action needed.
50
Not set
--- Reserved ---
53
Not set
--- Reserved ---
54
Minor
License
Management
Table Full
A new TCP/IP terminal
and the DSP board were
not able to be added to
the application license
management table.
• The license
management table is
registering full.
Maximum 51Minor license
information on the TCP/IP
terminal is registered, and a
new terminal cannot be
registered.
Please delete license
information on an
unnecessary TCP/IP
terminal with PRG 90-
44.