4
• Do not use the product when the cable or plug is damaged.
• Make sure that the electrical supply in your area matches a
voltage of 220 – 240 VAC and a frequency of 50 Hz.
• Connect to a grounded socket only.
• If necessary, use an earthed extension cable of a suitable
diameter.
• Fully extend the power cord and make sure the power cord does
not contact the product.
• When using an extension cord, use one which is as short as
possible and fully extended.
• Do not let the power cable touch hot surfaces.
• Do not close a door on the power cable.
• Do not pull the power cable to move the product.
• Do not put any objects into openings. Do not use with any
opening blocked.
• Do not use the product without the air inlet and outlet covers in
place to avoid touching hot and moving parts that may cause
injuries.
• Do not drink water from the product. This may cause illness.
• Be aware that the refrigerants should be odourless.
• The refrigerants should be added by the manufacturer, its service
agent or similar qualied persons.
• Do not use the product in temperatures below 0˚C.
• Do not expose the product to direct sunlight or rain.
• Do not spill any water on the product.
• Do not sit on the product.
• Unplug the power cable when the product is not in use for a long
time.
• Do not unplug the product by pulling on the cable. Always grasp
the plug and pull.
• Do not block the air in- and outlets of the product.
• Only install, operate and store the product in a room with a oor
area above 4 m
2
.
• Only store the product in a well-ventilated area.
• Do not use external timers or remote control systems to switch
the product on or o.
• Place the product in an area without any continuous sources of
ignition (for example: open ames, gas or electrical appliances in
operation).
• When the product is installed, operated or stored in a
non-ventilated area, make sure the room is designed to prevent
the accumulation of refrigerant leaks resulting in a risk of re or
explosion due to ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
• When defrosting and cleaning the product, do not use any
means other than those recommended by the manufacturing
company.
• Do not puncture or heat any part of the refrigerant circuit.
Installing the product
4
Keep a minimum of 300 mm of free space around the product.
4
Only move the product in the upright position.
1. Place the product on a stable and at surface.
2. Plug the power cable A
5
into a power outlet.
Assembling for continuous dehumidication
(optional)
1. Remove the plug from the water hose connection A
8
.
2. Place the water hose A
9
into A
8
.
3. Connect A
9
to a water container or drainage system (not
included).
4
Ensure that A
9
is hanging down from A
8
, so that the water
cannot ow back into the product.
Using the control panel
Button Function
Fan speed button B
q
Press during the dehumidication or
ventilation mode to switch between
the high and low fan speed.
The low fan speed B
2
or high fan
speed indicator LED B
1
lights up.
Timer button B
e
Press to cancel or set the duration of
dehumidication.
The timer can be set to a maximum
of 24 hours.
Press B
r
and B
t
to set the time.
The duration is shown in hours.
When the timer function is activated,
the time indicator LED B
3
lights up.
- button B
r
+ button B
t
Press to set the desired humidity level
within a range of 30% to 80%.
Dehumidify mode button
B
y
Press to choose from four dierent
modes:
Automatic
Dehumidication
Dry laundry
Ventilation
Power on / standby
button B
u
Press to switch the product on or o.
B
q
+ B
e
Press and hold B
q
and B
e
for 3
seconds to activate or deactivate the
child lock function.
The child lock indicator LED B
w
lights up.
4
The product might make some noise when it is used for the rst
time or after a long period when the product was not used. This
is normal and does not aect the safety of the product.
4
Keep the doors and windows closed to allow the product to work
more eciently.
4
The room temperature might increase during use, because the
product does not have a cooling function.
Operation modes
Automatic Automatically switches on and o to
maintain a humidity level of 55%.
Automatically switches to high fan
speed when the room humidity level
is higher than 70%.
Automatically switches to low fan
speed when the room humidity level
is between 55% and 70%.
Automatically switches to low fan
speed when the room humidity
level is lower than 55%. The
dehumidication function is disabled.
Set humidity level and fan speed are
disabled.
The automatic dehumidication
mode indicator LED B
7
lights up.
Dehumidication Switch on the dehumidication and
ventilator of the product.
The humidity level and fan speed can
be set manually.
The dehumidication mode indicator
LED B
6
lights up.
Dry laundry To help dry clothing and upholstery
in the room.
Set humidity level and fan speed are
disabled.
The dry laundry mode indicator LED
B
8
lights up.
DEHU10WT_MAN_COMP_0522_print.indd 4DEHU10WT_MAN_COMP_0522_print.indd 4 19-5-2022 13:02:0219-5-2022 13:02:02