Parameter 3: Basic Set Level
Basic Set Command will be sent where contains a value when motion sensor is triggered, Z-
Wave gateway will take it for consideration; for instance, if a lamp module is received
the Basic Set Command of which value is decisive as to how bright of dim level of lamp
module shall be.
Size: 1 Byte, Default Value: 99
Alarm cancelling or turning a device off
Parameter 4: PIR Detecting Function Enabled/Disabled
This parameter can enable or disable PIR detector detecting function.
Size: 1 Byte, Default Value: 255
Parameter 5: Ambient illumination Lux Level
This parameter can be set a lux level value which determines when light sensor is activated. If
the ambient illumination level falls below this value, and a person moves across or
stands within the detected area , PIR detector will send a Z-Wave ON command(i.e.
BASIC_SET value = parameter 3#) to an associated device and activate it.
Size: 2 Byte, Default Value: 100
Parameter 6: Re-trigger Interval Setting
This Parameter can be used to adjust the interval of being retriggered after PIR sensor has
been triggered. This Parameter value must be less than Parameter 2#.If user set
this parameter to default by Configure CC, the parameter #2 will be set to default value
Size: 1 Byte, Default Value: 8
Re-trigger Interval Setting.