EasyManua.ls Logo

NEO Coolcam NAS-DS01Z - Maintenance and Advanced Configuration; Restore Sensor to Factory Defaults; Battery Usage and Replacement; Advanced Configuration Parameters

NEO Coolcam NAS-DS01Z
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Restore the Sensor (door sensor) to Factory Default Settings
Reset will delete all information on the Z-Wave network or Z-Wave controller, and
restore the sensor to factory default settings.
1. Remove the cover of door sensor main body.
2. Make sure the sensor is connected to power source.
3. Press and hold the reset button for 10 seconds, LED light will flash red for 1 time.
4. Release the button.
NOTE
When the Door Sensor is being restored to factory default settings, please make sure
power source is connected.
Battery Usage Tips
Battery life of the door sensor is approximately 10 years at factory default settings.
The current battery level is displayed in the gateway. Red battery icon means the
battery needs replaced. In order to avoid tamper detection, while replacing the battery,
please disconnect the association of the door sensor with other devices.
Note
Door sensor is battery powered. Using batteries other than specified may result in
explosion. Dispose of properly, please observe environmental protection rules.
Advanced Configuration
1. Configuring the OFF Delay
This configuration parameter that can be used to adjust the amount of delay before the
OFF command is transmitted. This parameter can be configured with the value of 0
through 65535, where 0 means send OFF command immediately and 65535 means
65535 seconds of delay.
Function: On/Off Duration.
Parameter Number: 1.
Parameter Size: 2 Byte
Available Settings:0-65535 (in seconds, each 1s).
Default Setting: 30 (s)
2. Basic Set Level
Basic Set Command will be sent where contains a value when the door/window is
opened or closed, the receiver will take it for consideration; for instance, if a lamp
module received the Basic Set Command of which value is decisive as to how bright