Incidents – Causes – Remedies
Incidents
Pump does not start
No flow
Pump does not switch off
Insufficient flow
Pump switches of after short
operating period
Causes
No mains supply
Floater does not switch
Inlet sieve is clogged
Pressure hose in bent
Floater cannot sink down
Inlet sieve is clogged
Reduced pumping capacity by
dirty and abrasive water
Thermal cutout stops pumps
due to dirty water
Water too hot. Thermal-cutout
stops pump
Remedies
Check mains supply
Bring floater in a higher
position
Clean inlet sieve water jet
Reset hose
Place pump properly on shaft
ground
Clean inlet sieve
Clean pump and replace
worn-out parts
Remove mains plug. Clean
pump and shaft
Make sure that a water tem-
perature of max. 35°C is not
exceed