FUNCTION TESTS
9.3 Measure flow rate
The pressure adapter
must sit firmly in the
capsule bay.
1) Fill and insert water tank.
2) Open closing handle.
3) Insert connecting unit of pressure
adapter into capsule bay. Push back
sealing cone into capsule cage.
4) Insert fixation unit of pressure adapter
into capsule bay.
5) Press down operating lever.
6) Connect pressure hose to pressure
tester.
7) Place a measuring cup under the drain
hose of the pressure tester.
2.
1.
3.
4. 5.
6.
7.