Citiz service manual
95
REPAIRS
8.7.2
Replacing electronic control board with button prints
• Refer to page 93 for removing cover (2).
• Remove first
- NTC connector from electronic control board,
- connector cable from flow meter,
- electronic lid (43),
- faston receptacles from electronic control board.
• Insert tip of screwdriver between chassis (1) and protective case of electronic control
board (42) to release latches. Then pull out assembly.