F U N C T I O N T E S T S
6. Presscoffeebutton"mediumcup".
Theprogrammedcuplenghtshouldbe40mlormore.
7. Waituntilthemeasuringcupcontains20mlofcoffee.
8. Thenmeasurethecoffeetemperatureapprox.510mmunderthecoffeeoutlet.
Thecoffeetem peratureshouldbe86°C±3°C(187°F±5.4°F).
9. Ifnecessary,changecoffeetemperaturegraduallywiththehelpofmenupoint
"coffeetemperature"(see"Powerusermenupoints"onpage30).
Thismenupointsettingisvalidfor bothcoffee units.