EasyManua.ls Logo

netAlly CyberScope Air - Page 287

netAlly CyberScope Air
755 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Timeout Threshold
This threshold controls how long the
CyberScope Air waits for a response from the
target before failing the test.
Reverse Grading
When Reverse Grading is enabled, a test is
considered successful if it fails and a failure if it
succeeds. The Results Codes section of the
results screen includes the message "Grading
has been reversed".
For example, you might have a critical server
used by an accounting department. This server
must be accessible by the accounting VLAN not
by any other networks. To verify the con-
figuration, you could set up a Ping test to with
Reverse Grading enabled. Running a Wi-Fi
AutoTest profile to the server's guest SSID with
the reverse graded test reports a ping failure,
which is the desired outcome.