If the impaired controller is
displaying…
Then…
System prompt or password
prompt
Take over or halt the impaired controller from the healthy controller:
storage failover takeover -ofnode
impaired_node_name
When the impaired controller shows Waiting for giveback…, press
Ctrl-C, and then respond
y.
Step 2: Remove the controller module
You must remove the controller module from the chassis when you replace a fan module.
1. If you are not already grounded, properly ground yourself.
2. Unplug the controller module power supplies from the source.
3. Release the power cable retainers, and then unplug the cables from the power supplies.
4. Loosen the hook and loop strap binding the cables to the cable management device, and then unplug the
system cables from the controller module, keeping track of where the cables were connected.
Leave the cables in the cable management device so that when you reinstall the cable management
device, the cables are organized.
5. Remove the cable management device from the controller module and set it aside.
6. Press down on both of the locking latches, and then rotate both latches downward at the same time.
The controller module moves slightly out of the chassis.
652

Other manuals for NetApp AFF A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp AFF A Series and is the answer not in the manual?

NetApp AFF A Series Specifications

General IconGeneral
BrandNetApp
ModelAFF A Series
CategoryServer
LanguageEnglish

Related product manuals