If the impaired node is
displaying…
Then…
The LOADER prompt Go to Remove controller module..
Waiting for giveback…
Press Ctrl-C, and then respond y when prompted.
System prompt or password
prompt (enter system password)
Take over or halt the impaired node from the healthy node: storage
failover takeover -ofnode impaired_node_name
+ When the impaired node shows Waiting for giveback…, press Ctrl-
C, and then respond
y.
+
Step 2: Replace the NVRAM module
To replace the NVRAM module, locate it in slot 6 in the chassis and follow the specific
sequence of steps.
1. If you are not already grounded, properly ground yourself.
2. Remove the target NVRAM module from the chassis:
a. Depress the lettered and numbered cam button.
The cam button moves away from the chassis.
b. Rotate the cam latch down until it is in a horizontal position.
The NVRAM module disengages from the chassis and moves out a few inches.
c. Remove the NVRAM module from the chassis by pulling on the pull tabs on the sides of the module
face.
Animation—Replace the NVRAM module