Step 7: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part Return
& Replacements
page for further information.
Replace a PCIe or mezzanine card - ASA C400
To replace a PCIe or mezzanine card, you must disconnect the cables and any SFP and
QSFP modules from the cards, replace the failed PCIe or mezzanine card, and then
recable the cards.
You can use this procedure with all versions of ONTAP supported by your system
All other components in the system must be functioning properly; if not, you must contact technical support.
Step 1: Shut down the impaired controller
You can shut down or take over the impaired controller using different procedures, depending on the storage
system hardware configuration.