controller_A_1::> storage aggregate show
Aggregate Size Available Used% State #Vols Nodes
RAID Status
--------- -------- --------- ----- ------- ------ ----------------
------------
...
aggr_b2 227.1GB 227.1GB 0% online 0 mcc1-a2
raid_dp, mirrored, normal...
6.
Heal the root aggregates by using the
metrocluster heal -phase root-aggregates
command.
mcc1A::> metrocluster heal -phase root-aggregates
[Job 137] Job succeeded: Heal Root Aggregates is successful
If the healing is vetoed, you have the option of reissuing the metrocluster heal command with
the -override-vetoes parameter. If you use this optional parameter, the system overrides any soft
vetoes that prevent the healing operation.
7.
Verify that the heal operation is complete by using the
metrocluster operation show command
on the destination cluster:
mcc1A::> metrocluster operation show
Ê Operation: heal-root-aggregates
Ê State: successful
ÊStart Time: 7/29/2016 20:54:41
Ê End Time: 7/29/2016 20:54:42
Ê Errors: -
8. On the impaired controller module, disconnect the power supplies.
= Replace the boot media - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
To replace the boot media, you must remove the impaired controller module, install
the replacement boot media, and transfer the boot image to a USB flash drive.
== Step 1: Remove the controller module
To access components inside the controller module, you must remove the controller module from the
chassis.
You can use the following animation, illustration, or the written steps to remove the controller module from
the chassis.
117