synchronize.
If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the
process. See the appropriate Documentation Center for more information.
11.
Once the giveback completes, check the failover and giveback status with the
storage failover
show
and `storage failover show-giveback` commands.
Only the CFO aggregates (root aggregate and CFO style data aggregates) will be shown.
12. Move the console cable to the target controller.
a. If you are running ONTAP 9.6 or later, run the security key-manager onboard sync:
b.
Run the
security key-manager onboard sync command and then enter the passphrase
when prompted.
c.
Enter the
security key-manager key query command to see a detailed view of all keys
stored in the onboard key manager and verify that the
Restored column = yes/true for all
authentication keys.
If the Restored column = anything other than yes/true, contact Customer
Support.
d. Wait 10 minutes for the key to synchronize across the cluster.
13. Move the console cable to the partner controller.
14.
Give back the target controller using the
storage failover giveback -fromnode local
command.
15.
Check the giveback status, 3 minutes after it reports complete, using the
storage failover show
command.
If giveback is not complete after 20 minutes, contact Customer Support.
16.
At the clustershell prompt, enter the
net int show -is-home false command to list the logical
interfaces that are not on their home controller and port.
If any interfaces are listed as
false, revert those interfaces back to their home port using the net
int revert -vserver Cluster -lif nodename
command.
17.
Move the console cable to the target controller and run the
version -v command to check the
ONTAP versions.
18.
Restore automatic giveback if you disabled it by using the
storage failover modify -node
local -auto-giveback true
command.
== Restore NSE/NVE on systems running ONTAP 9.6 and later
Steps
1. Connect the console cable to the target controller.
2.
Use the
boot_ontap command at the LOADER prompt to boot the controller.