Manager type.
Use the
security key-manager key query command to verify that the Restored column =
yes/true for all authentication keys.
11. Connect the console cable to the partner controller.
12.
Give back the controller using the
storage failover giveback -fromnode local command.
13.
Restore automatic giveback if you disabled it by using the
storage failover modify -node
local -auto-giveback true
command.
= Return the failed part to NetApp - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Return the failed part to NetApp, as described in the RMA instructions shipped with
the kit. See the
Part Return & Replacements page for further information.
= Chassis
= Overview of chassis replacement - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
To replace the chassis, you must move the fans and controller modules from the
impaired chassis to the new chassis of the same model as the impaired chassis.
All other components in the system must be functioning properly; if not, you must contact technical
support.
You can use this procedure with all versions of ONTAP supported by your system.
This procedure is disruptive. For a two-node cluster, you will have a complete service outage and a
partial outage in a multinode cluster.
= Shut down the controllers - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Shut down or take over the impaired controller using the appropriate procedure for
your configuration.
== Option 1: Shut down the controllers when replacing a chassis
This procedure is for 2-node, non-MetroCluster configurations only. If you have a system with more than
two nodes, see
How to perform a graceful shutdown and power up of one HA pair in a 4-node cluster.
Before you begin
You need:
130