interrupt the boot process.
d. If you have not already done so, reinstall the cable management device.
e.
Interrupt the normal boot process and boot to LOADER by pressing
Ctrl-C.
If your system stops at the boot menu, select the option to boot to LOADER.
f.
At the LOADER prompt, enter
bye to reinitialize the PCIe cards and other components.
g.
Interrupt the boot process and boot to the LOADER prompt by pressing
Ctrl-C.
If your system stops at the boot menu, select the option to boot to LOADER.
= Restore and verify the system configuration - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
After completing the hardware replacement and booting to Maintenance mode, you
verify the low-level system configuration of the replacement controller and
reconfigure system settings as necessary.
== Step 1: Set and verify system time after replacing the controller
You should check the time and date on the replacement controller module against the healthy controller
module in an HA pair, or against a reliable time server in a stand-alone configuration. If the time and date
do not match, you must reset them on the replacement controller module to prevent possible outages on
clients due to time differences.
About this task
It is important that you apply the commands in the steps on the correct systems:
The replacement node is the new node that replaced the impaired node as part of this procedure.
The healthy node is the HA partner of the replacement node.
Steps
1. If the replacement node is not at the LOADER prompt, halt the system to the LOADER prompt.
2.
On the healthy node, check the system time:
cluster date show
The date and time are based on the configured timezone.
3.
At the LOADER prompt, check the date and time on the replacement node:
show date
The date and time are given in GMT.
4.
If necessary, set the date in GMT on the replacement node:
set date mm/dd/yyyy
5.
If necessary, set the time in GMT on the replacement node:
set time hh:mm:ss
6.
At the LOADER prompt, confirm the date and time on the replacement node: date
The date and time are given in GMT.
152