using the metrocluster config-replication resync-status show command.
6. Reestablish any SnapMirror or SnapVault configurations.
== Step 4: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part
Return & Replacements
page for further information.
= Replace a DIMM - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
You must replace a DIMM in the controller module when your system registers an
increasing number of correctable error correction codes (ECC); failure to do so
causes a system panic.
All other components in the system must be functioning properly; if not, you must contact technical
support.
You must replace the failed component with a replacement FRU component you received from your
provider.
== Step 1: Shut down the impaired controller
Shut down or take over the impaired controller using the appropriate procedure for your configuration.