successfully: metrocluster check lif show
4.
Perform the switchback by using the
metrocluster switchback command from any node in the
surviving cluster.
5.
Verify that the switchback operation has completed:
metrocluster show
The switchback operation is still running when a cluster is in the waiting-for-switchback state:
cluster_B::> metrocluster show
Cluster Configuration State Mode
-------------------- ------------------- ---------
ÊLocal: cluster_B configured switchover
Remote: cluster_A configured waiting-for-switchback
The switchback operation is complete when the clusters are in the normal state.:
cluster_B::> metrocluster show
Cluster Configuration State Mode
-------------------- ------------------- ---------
ÊLocal: cluster_B configured normal
Remote: cluster_A configured normal
If a switchback is taking a long time to finish, you can check on the status of in-progress baselines by
using the
metrocluster config-replication resync-status show command.
6. Reestablish any SnapMirror or SnapVault configurations.
== Step 8: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part
Return & Replacements
page for further information.
= Replacing a power supply - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Replacing a power supply (PSU) involves disconnecting the target PSU from the
power source, unplugging the power cable, removing the old PSU and installing the
replacement PSU, and then reconnecting the replacement PSU to the power source.
The power supplies are redundant and hot-swappable.
This procedure is written for replacing one power supply at a time.
It is a best practice to replace the power supply within two minutes of removing it from
the chassis. The system continues to function, but ONTAP sends messages to the
console about the degraded power supply until the power supply is replaced.