key IDs of the authentication keys.
If the command fails, contact Customer Support.
◦
If the
Key Manager type = onboard and the Restored column = anything other than
yes/true, use the security key-manager onboard sync command to re-sync the Key
Manager type.
Use the security key-manager key query to verify that the
Restored column = yes/true for all
authentication keys.
11. Connect the console cable to the partner controller.
12.
Give back the controller using the
storage failover giveback -fromnode local command.
13.
Restore automatic giveback if you disabled it by using the
storage failover modify -node
local -auto-giveback true
command.
14.
Restore Autosupport if it was disabled by using the
system node autosupport invoke -node
* -type all -message MAINT=END
= Return the failed part to NetApp - ASA C800
:icons: font
:relative_path: ./asa-c-800/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Return the failed part to NetApp, as described in the RMA instructions shipped with
the kit. See the
Part Return & Replacements page for further information.
= Chassis
= Replace the chassis - ASA C800
:icons: font
:relative_path: ./asa-c-800/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
To replace the chassis, you must move the bezel, controller modules, and NVMe
drives from the impaired chassis to the replacement chassis, and then remove the
impaired chassis from the equipment rack or system cabinet and install the
replacement chassis in its place.
All other components in the system must be functioning properly; if not, you must contact technical
support.
• You can use this procedure with all versions of ONTAP supported by your system.
• This procedure is written with the assumption that you are moving the bezel, NVMe drives, and
controller modules to the new chassis, and that the replacement chassis is a new component from
NetApp.
• This procedure is disruptive. For a two-node cluster, you will have a complete service outage and a
partial outage in a multi-node cluster.
= Shut down the controllers - ASA C800