If your system does not have onboard keymanager, NSE or NVE configured, complete the steps in this
section.
6.
From the LOADER prompt, enter the
boot_ontap command.
If you see… Then…
The login prompt Go to the next Step.
Waiting for giveback… a. Log into the partner controller.
b. Confirm the target controller is ready for giveback with the
storage failover show command.
7. Connect the console cable to the partner controller.
8.
Give back the controller using the
storage failover giveback -fromnode local command.
9.
At the cluster prompt, check the logical interfaces with the
net int -is-home false command.
If any interfaces are listed as "false", revert those interfaces back to their home port using the
net int
revert
command.
10.
Move the console cable to the repaired controller and run the
version -v command to check the ONTAP
versions.
11.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.