grace period ends.
Steps
1. If you need new license keys, obtain replacement license keys on the
NetApp Support Site in the My
Support section under Software licenses.
The new license keys that you require are automatically generated and sent to the
email address on file. If you fail to receive the email with the license keys within 30
days, you should contact technical support.
2.
Install each license key:
system license add -license-code license-key, license-
key...
3. Remove the old licenses, if desired:
a.
Check for unused licenses:
license clean-up -unused -simulate
b.
If the list looks correct, remove the unused licenses:
license clean-up -unused
== Step 2: Verify LIFs and registering the serial number
Before returning the replacement node to service, you should verify that the LIFs are on their home ports,
and register the serial number of the replacement node if AutoSupport is enabled, and reset automatic
giveback.
Steps
1.
Verify that the logical interfaces are reporting to their home server and ports:
network interface
show -is-home false
If any LIFs are listed as false, revert them to their home ports: network interface revert
-vserver * -lif *
2. Register the system serial number with NetApp Support.
If AutoSupport is enabled, send an AutoSupport message to register the serial number.
If AutoSupport is not enabled, call NetApp Support to register the serial number.
3.
If an AutoSupport maintenance window was triggered, end it by using the
system node
autosupport invoke -node * -type all -message MAINT=END
command.
4.
If automatic giveback was disabled, reenable it:
storage failover modify -node local
-auto-giveback true
== Step 3: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part
Return & Replacements
page for further information.
= Replace a DIMM - ASA C250
:icons: font
:relative_path: ./asa-c-250/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
You must replace a DIMM in the controller module when your system registers an
increasing number of correctable error correction codes (ECC); failure to do so
59