Step 8: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the
kit. See the
Part Return & Replacements page for further information.
Replace an NVDIMM - AFF C400
You must replace the NVDIMM in the controller module when your system registers that
the flash lifetime is almost at an end or that the identified NVDIMM is not healthy in
general; failure to do so causes a system panic.
All other components in the system must be functioning properly; if not, you must contact technical support.
You must replace the failed component with a replacement FRU component you received from your provider.
Step 1: Shut down the impaired controller
Shut down or take over the impaired controller using the appropriate procedure for your
configuration.