If the
Key Manager type = external and the Restored column = anything other than
yes/true, use the security key-manager external restore command to restore the
key IDs of the authentication keys.
If the command fails, contact Customer Support.
If the
Key Manager type = onboard and the Restored column = anything other than
yes/true, use the security key-manager onboard sync command to re-sync the Key
Manager type.
Use the
security key-manager key query command to verify that the Restored column =
yes/true for all authentication keys.
11. Connect the console cable to the partner controller.
12.
Give back the controller using the
storage failover giveback -fromnode local command.
13.
Restore automatic giveback if you disabled it by using the
storage failover modify -node
local -auto-giveback true
command.
= Return the failed part to NetApp - ASA A250 :icons: font :relative_path: ./asa250/ :imagesdir:
/tmp/d20230728-13098-1ncp8ai/source/./asa250/../media/
Return the failed part to NetApp, as described in the RMA instructions shipped with
the kit. See the
Part Return & Replacements page for further information.
= Chassis
= Overview of chassis replacement - ASA A250 :icons: font :relative_path: ./asa250/ :imagesdir:
/tmp/d20230728-13098-1ncp8ai/source/./asa250/../media/
To replace the chassis, you must move the bezel, controller modules, and NVMe
drives from the impaired chassis to the replacement chassis, and then remove the
impaired chassis from the equipment rack or system cabinet and install the
replacement chassis in its place.
About this task
All other components in the system must be functioning properly; if not, you must contact technical
support.
You can use this procedure with all versions of ONTAP supported by your system.
This procedure is written with the assumption that you are moving the bezel, NVMe drives, and
controller modules to the new chassis, and that the replacement chassis is a new component from
NetApp.
This procedure is disruptive. For a two-node cluster, you will have a complete service outage and a
partial outage in a multi-node cluster.
= Shut down the controllers - ASA A250 :icons: font :relative_path: ./asa250/ :imagesdir: /tmp/d20230728-
13098-1ncp8ai/source/./asa250/../media/
This procedure is for 2-node, non-MetroCluster configurations only. If you have a
system with more than two nodes, see
How to perform a graceful shutdown and
36