The controller module should be fully inserted and flush with the edges of the chassis.
5. Repeat the preceding steps to install the second controller into the new chassis.
= Complete the restoration and replacement process - ASA A250 :icons: font :relative_path: ./asa250/
:imagesdir: /tmp/d20230728-13098-1ncp8ai/source/./asa250/../media/
You must verify the HA state of the chassis, and return the failed part to NetApp, as
described in the RMA instructions shipped with the kit.
== Step 1: Verify and set the HA state of the chassis
You must verify the HA state of the chassis, and, if necessary, update the state to match your system
configuration.
1. In Maintenance mode, from either controller module, display the HA state of the local controller
module and chassis:
ha-config show
The HA state should be the same for all components.
2. If the displayed system state for the chassis does not match your system configuration:
a.
Set the HA state for the chassis:
ha-config modify chassis HA-state
The value for HA-state can be one of the following:
ha
mcc
mccip
non-ha
b.
Confirm that the setting has changed:
ha-config show
3. If you have not already done so, recable the rest of your system.
4. Reinstall the bezel on the front of the system.
== Step 2: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part
Return & Replacements
page for further information.
= Controller
= Overview of controller module replacement- ASA A250 :icons: font :relative_path: ./asa250/ :imagesdir:
/tmp/d20230728-13098-1ncp8ai/source/./asa250/../media/
You must review the prerequisites for the replacement procedure and select the
correct one for your version of the ONTAP operating system.
All drive shelves must be working properly.
If your system is in a MetroCluster configuration, you must review the section
Choosing the correct
recovery procedure to determine whether you should use this procedure.