EasyManuals Logo

NetApp FAS User Manual

NetApp FAS
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
During the boot process, you can safely respond y to the prompts until the Maintenance mode prompt (*>)
appears.
3.
Run diagnostics on the NVMEM memory:
sldiag device run -dev nvmem
4.
Verify that no hardware problems resulted from the replacement of the NVMEM battery:
sldiag device
status -dev nvmem -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status of
failures resulting from testing the component.
5. Proceed based on the result of the preceding step:
If the system-level diagnostics
tests…
Then…
Were completed without any
failures
a.
Clear the status logs:
sldiag device clearstatus
b.
Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c.
Exit Maintenance mode:
halt
The controller displays the LOADER prompt.
d.
Boot the controller from the LOADER prompt:
bye
e. Return the controller to normal operation:
If your controller is in… Then…
An HA pair
Perform a give back: storage failover giveback -ofnode
replacement_node_name
If you disabled automatic giveback, re-enable it with
the storage failover modify command.
A stand-alone configuration Proceed to the next step.
No action is required.
You have completed system-level diagnostics.
173

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp FAS and is the answer not in the manual?

NetApp FAS Specifications

General IconGeneral
BrandNetApp
ModelFAS
CategoryDisk array system
LanguageEnglish

Related product manuals