If the impaired controller is
displaying…
Then…
System prompt or password
prompt (enter system password)
Take over or halt the impaired controller from the healthy controller:
storage failover takeover -ofnode
impaired_node_name
When the impaired controller shows Waiting for giveback…, press
Ctrl-C, and then respond
y.
4. If the system has only one controller module in the chassis, turn off the power supplies, and then unplug
the impaired controller’s power cords from the power source.
Step 2: Remove controller module
To access components inside the controller, you must first remove the controller module from the system and
then remove the cover on the controller module.
1. If you are not already grounded, properly ground yourself.
2. Loosen the hook and loop strap binding the cables to the cable management device, and then unplug the
system cables and SFPs (if needed) from the controller module, keeping track of where the cables were
connected.
Leave the cables in the cable management device so that when you reinstall the cable management
device, the cables are organized.
3. Remove and set aside the cable management devices from the left and right sides of the controller module.
4. Squeeze the latch on the cam handle until it releases, open the cam handle fully to release the controller
module from the midplane, and then, using two hands, pull the controller module out of the chassis.
178