3. Recable the system, as needed.
If you removed the media converters (QSFPs or SFPs), remember to reinstall them if you are using fiber
optic cables.
4. If the power supplies were unplugged, plug them back in and reinstall the power cable retainers.
5. Complete the reinstallation of the controller module:
a. With the cam handle in the open position, firmly push the controller module in until it meets the
midplane and is fully seated, and then close the cam handle to the locked position.
Do not use excessive force when sliding the controller module into the chassis to avoid
damaging the connectors.
b. If you have not already done so, reinstall the cable management device.
c. Bind the cables to the cable management device with the hook and loop strap.
d. Reconnect the power cables to the power supplies and to the power sources, and then turn on the
power to start the boot process.
e. Halt the controller at the LOADER prompt.
6. Reset the time and date on the controller:
a.
Check the date and time on the healthy controller with the
show date command.
b. At the LOADER prompt on the target controller, check the time and date.
c.
If necessary, modify the date with the
set date mm/dd/yyyy command.
d.
If necessary, set the time, in GMT, using the
set time hh:mm:ss command.
e. Confirm the date and time on the target controller.
7.
At the LOADER prompt, enter
bye to reinitialize the PCIe cards and other components and let the
controller reboot.
8.
Return the controller to normal operation by giving back its storage:
storage failover giveback
-ofnode impaired_node_name
9.
If automatic giveback was disabled, reenable it:
storage failover modify -node local -auto
-giveback true
Step 5: Complete the replacement process
After you replace the part, you can return the failed part to NetApp, as described in the RMA instructions
shipped with the kit. Contact technical support at
NetApp Support, 888-463-8277 (North America), 00-800-44-
638277 (Europe), or +800-800-80-800 (Asia/Pacific) if you need the RMA number or additional help with the
replacement procedure.
FAS2700 System Documentation
Install and setup
Start here: Choose your installation and setup experience
For most configurations, you can choose from different content formats.
181

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp FAS and is the answer not in the manual?

NetApp FAS Specifications

General IconGeneral
BrandNetApp
ModelFAS
CategoryDisk array system
LanguageEnglish

Related product manuals