EasyManuals Logo

NetApp FAS User Manual

NetApp FAS
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #218 background imageLoading...
Page #218 background image
b.
Enter the
key-manager key show -detail command to see a detailed view of all keys stored in
the onboard key manager and verify that the
Restored column = yes for all authentication keys.
If the Restored column = anything other than yes, contact Customer Support.
c. Wait 10 minutes for the key to synchronize across the cluster.
14. If you are running ONTAP 9.6 or later:
a.
Run the
security key-manager onboard sync command and then enter the passphrase when
prompted.
b.
Enter the
security key-manager key query command to see a detailed view of all keys stored
in the onboard key manager and verify that the
Restored column = yes/true for all authentication
keys.
If the Restored column = anything other than yes/true, contact Customer Support.
c. Wait 10 minutes for the key to synchronize across the cluster.
15. Move the console cable to the partner controller.
16.
Give back the target controller using the
storage failover giveback -fromnode local
command.
17.
Check the giveback status, 3 minutes after it reports complete, using the
storage failover show
command.
If giveback is not complete after 20 minutes, contact Customer Support.
18.
At the clustershell prompt, enter the
net int show -is-home false command to list the logical
interfaces that are not on their home controller and port.
If any interfaces are listed as
false, revert those interfaces back to their home port using the net int
revert
command.
19.
Move the console cable to the target controller and run the
version -v command to check the ONTAP
versions.
20.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Option 2: Restore NSE/NVE on systems running ONTAP 9.5 and earlier
Steps
1. Connect the console cable to the target controller.
2.
Use the
boot_ontap command at the LOADER prompt to boot the controller.
3. Check the console output:
If the console
displays…
Then…
The login prompt Go to Step 7.
216

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp FAS and is the answer not in the manual?

NetApp FAS Specifications

General IconGeneral
BrandNetApp
ModelFAS
CategoryDisk array system
LanguageEnglish

Related product manuals