4.
Verify that no hardware problems resulted from the replacement of the caching module:
sldiag device
status -dev fcache -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status of
failures resulting from testing the component.
5. Proceed based on the result of the preceding step:
If the system-level diagnostics
tests…
Then…
Were completed without any
failures
a.
Clear the status logs:
sldiag device clearstatus
b.
Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c.
Exit Maintenance mode:
halt
The controller displays the LOADER prompt.
d.
Boot the controller from the LOADER prompt:
bye
e. Return the controller to normal operation:
If your controller is in… Then…
An HA pair
Perform a give back: storage failover giveback -ofnode
replacement_node_name
If you disabled automatic giveback, re-enable it with
the storage failover modify command.
A two-node MetroCluster
configuration
Proceed to the next step.
The MetroCluster switchback procedure is done in the next task in the
replacement process.
A stand-alone configuration Proceed to the next step. No action is required. You have completed