9. After you have completed the initial configuration, go to the ONTAP & ONTAP System Manager
Documentation Resources
page for information about configuring additional features in ONTAP.
Maintain
Boot media
Overview of boot media replacement - AFF A700 and FAS9000
The boot media stores a primary and secondary set of system (boot image) files that the system uses when it
boots. Depending on your network configuration, you can perform either a nondisruptive or disruptive
replacement.
You must have a USB flash drive, formatted to FAT32, with the appropriate amount of storage to hold the
image_xxx.tgz.
You also must copy the
image_xxx.tgz file to the USB flash drive for later use in this procedure.
•
The nondisruptive and disruptive methods for replacing a boot media both require you to restore the
var
file system:
â—¦
For nondisruptive replacement, the HA pair does not require connection to a network to restore the
var
file system. The HA pair in a single chassis has an internal e0S connection, which is used to transfer
var config between them.
â—¦
For disruptive replacement, you do not need a network connection to restore the
var file system, but
the process requires two reboots.
• You must replace the failed component with a replacement FRU component you received from your
provider.
• It is important that you apply the commands in these steps on the correct node:
â—¦ The impaired node is the node on which you are performing maintenance.
â—¦ The healthy node is the HA partner of the impaired node.
Check onboard encryption keys
Prior to shutting down the impaired controller and checking the status of the onboard
encryption keys, you must check the status of the impaired controller, disable automatic
giveback, and check the version of ONTAP that is running.
If you have a cluster with more than two nodes, it must be in quorum. If the cluster is not in quorum or a healthy
controller shows false for eligibility and health, you must correct the issue before shutting down the impaired
controller; see the
NetApp Encryption overview with the CLI.
Steps
1. Check the status of the impaired controller:
â—¦
If the impaired controller is at the login prompt, log in as
admin.
â—¦
If the impaired controller is at the LOADER prompt and is part of HA configuration, log in as
admin on
the healthy controller.
â—¦ If the impaired controller is in a standalone configuration and at LOADER prompt, contact
mysupport.netapp.com.