INTRODUCTION
Enginecoolant
NEWHOLLANDCONSTRUCTIONrequirestheuseofafullyformulatedOrganicAcidT echnology(OAT)based
coolant.NEWHOLLANDAMBRAACTIFULL™OTEXTENDEDLIFECOOLANTisthereferencegenuineproduct.
NOTICE:useofdifferentcoolantbrandsisnotrecommended.
NOTICE:neveraddSupplementalCoolantAdditives(SCA)whenusingNEWHOLLANDAMBRAACTIFULL™OT
EXTENDEDLIFECOOLANT.
NOTICE:nevermixNEWHOLLANDAMBRAACTIFULL™OTEXTENDEDLIFECOOLANTcoolantwithconven-
tionalcoolant.MixingOATbasedcoolantwithconventionalcoolantwillreducetheeffectivenessofOATcoolant.
NOTICE:ifonlyconventionalcoolantisavailable,acompletechangeoveroftheuidintothecoolingsystemshallbe
carriedout.
theenginecoolingsystemshallalwaysberelledwithcoolantsolutionmadebymixtureofantifreezeanddistilled
(deionized)water.
NOTICE:neverrellthecoolingsystemwithonlyantifreeze.Neverrellthecoolingsystemwithonlywater.
UsingNEWHOLLANDAMBRAACTIFULL™OTEXTENDEDLIFECOOLANT,a50/50mixtureofantifreezeand
distilled(deionized)watergrantsproperperformanceoftheenginecoolingsystemintheabovementionedoperating
temperaturerangeofthemachine.
NEWHOLLANDAMBRAACTIFULL™OTEXTENDEDLIFECOOLANTisavailableas:
•
50/50PREMIXEDcoolantsolutionreadyforusage.
•
CONCENTRATEantifreezetobemixed50/50withdistilled(deionized)water.
NOTICE:ifoperatinginextremewinterclimate,acoolantsolutionmadeby60/40antifreeze/distilled(deionized)water
mixtureshallbeusedinordertograntproperperformanceoftheenginecoolingsystem.
NOTICE:neverusecoolantsolutionwithmorethan60%ofantifreeze.Thisaffectsthecoolingcapacityofthemixture.
WhenthecoolantsolutionispreparedstartingfromtheCONCENTRATEproduct,theantifreezeconcentrationinthe
mixtureofantifreezeanddistilled(deionized)watercanbedeterminedwitharefractometerdesignedtomeasure
ethyleneglycolcontent.
Ifdistilled(deionized)waterisnotavailable,usewaterfordilutionwiththefollowingproperties:
PropertyMaximumlimit
TotalSolids
340ppm
TotalHardness340ppm
Chloride(Cl)
340ppm
Sulfate(SO4)
100ppm
AciditypH5.5to9.0
NOTICE:neverusehardwater,seawaterandsoftenedseawaterthathasbeenconditionedwithsalt.Theminerals
andsaltspresentinpotablewatercancausecorrosionanddepositsresultinginshortenedenginelife.