6-MAINTENANCE
Every5000hours
Hydraulicoil
WARNING
Burnhazard!
Beforeperforminganyserviceonthehydraulicsystem,youmustallowittocool.Hydraulicuid
temperatureshouldnotexceed40°C(104°F).
Failuretocomplycouldresultindeathorseriousinjury.
W0241A
WARNING
Pressurizedsystem!
Neverattempttodrainuidsorremovelterswhentheengineisrunning.Turnofftheengineand
relieveallpressurefrompressurizedsystemsbeforeservicingthemachine.
Failuretocomplycouldresultindeathorseriousinjury.
W0905A
WARNING
Escapinguid!
Hydraulicuidordieselfuelleakingunderpressurecanpenetratetheskinandcauseinfectionor
otherinjury.Topreventpersonalinjury:Relieveallpressurebeforedisconnectinguidlinesorper-
formingworkonthehydraulicsystem.Beforeapplyingpressure,makesureallconnectionsaretight
andallcomponentsareingoodcondition.Neveruseyourhandtocheckforsuspectedleaksunder
pressure.Useapieceofcardboardorwoodforthispurpose.Ifinjuredbyleakinguid,seeyour
doctorimmediately.
Failuretocomplycouldresultindeathorseriousinjury.
W0178A
Replacethehydraulicoilevery5000h
Fluid:PREMIUMHYDRAULICOILHV46MULTI-GRADEANTIWEAR
Quantity:37L(9.8USgal)
NOTICE:whenusingthehydraulicbreaker,reducetheintervalofthehydraulicoilreplacement.RefertopageHy-
draulicoil-breaker/auger
1.Releaseallthepressureinthehydraulictank.Referto
page6-10.
2.Lowerthebucketonthegroundpullingthearmand
bucketcylindertothemaximumcylinderextension.
6-65