13
Setting voltage point
back to battery mode
when selecting “SBU
priority” or “Solar first”
in program 01.
51V
52V
53V
54V (default)
55V
56V
57V
58V
16
Charger source priority:
To configure charger
source priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar first
Solar energy will charge battery as first
priority.
Utility will charge battery only when
solar energy is not available.
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar and Utility (default)
Solar energy and utility will charge
battery at the same time.
Only Solar
Solar energy will be the only charger
source no matter utility is available or
not.
If this inverter/charger is working in Battery mode or Power saving
mode, only solar energy can charge battery. Solar energy will charge
battery if it's available and sufficient.
Alarm on (default)
Alarm off
Auto return to default
display screen
Return to default display
screen (default)
If selected, no matter how users switch
display screen, it will automatically
return to default display screen (Input
voltage /output voltage) after no button
is pressed for 1 minute.
Stay at latest screen
If selected, the display screen will stay
at latest screen user finally switches.
19