EasyManuals Logo

NI RTI-12309 Safety, Environmental, And Regulatory Information

NI RTI-12309
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION
RTI-12309
Rear Transition Interface for Generic DIO/AO/AI with 8 IX Headers
Read this document before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring
instructions in addition to requirements of all applicable codes, laws, and standards. Visit ni.com/manuals for more information about your product, including
specifications, pinouts, and instructions for connecting, installing, and configuring your system.
Icons
Refer to the following descriptions if one of these icons is marked on your product or used in this guide.
Notice Take precautions to avoid data loss, loss of signal integrity, degradation of performance, or damage to the product.
Caution Take precautions to avoid injury. Consult the product documentation for cautionary statements when you see this icon printed on the
product. Cautionary statements are localized into French for compliance with Canadian requirements.
Safety Guidelines
Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and
compromise the built-in safety protection.
Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation d'utilisation. L'utilisation du produit de toute autre
façon que celle spécifiée risque de l'endommager et de compromettre la protection de sécurité intégrée.
Safety Current and Voltage Limits
Maximum working current and voltage
JR1 8 A per contact, 60 V DC
JR2 to JR9 0.75 A per contact, 32 V peak
Maximum working voltage refers to the signal voltage plus the common-mode voltage, and applies to both channel-to-channel and channel-to-earth.
Caution Do not supply hazardous voltages (>30 V
RMS
/42 V
peak
/60 V
dc
) to the RTI-12309.
Attention Ne pas alimenter le RTI-12309 avec des tensions dangereuses (> 30 V
eff
/ 42 V
pic
/ 60 V
cc
).
Caution Do not connect the RTI-12309 to signals or use for measurements within Measurement Categories II, III, or IV.
Attention Ne connectez pas le RTI-12309 à des signaux et ne l'utilisez pas pour effectuer des mesures dans les catégories de mesure II, III ou IV.
Caution Source must be limited to not exceed rated maximum current and voltage.
Attention La source doit être limitée de manière à ne pas dépasser le courant nominal maximal, ni la tension nominale maximale.
This product is rated for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS.
MAINS is a hazardous live electrical supply system to which equipment is designed to be connected to for the purpose of powering equipment. This product is
rated for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-
energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
IEC 61010-1, EN 61010-1
UL 61010-1, CSA C22.2 No. 61010-1
Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

Other manuals for NI RTI-12309

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NI RTI-12309 and is the answer not in the manual?

NI RTI-12309 Specifications

General IconGeneral
BrandNI
ModelRTI-12309
CategoryRecording Equipment
LanguageEnglish