1.
Browse to the function page.
2.
Press the screen with your finger.
3.
Select the required offset.
4.
Save by pressing the green button.
The number of steps by which the value has to be
changed, to obtain a one degree change in the indoor
temperature, depends on the house’s climate unit.
Perhaps one step for floor coils, while radiators may re-
quire three steps.
Setting the temperature (with controlling room
sensor activated):
Setting range: 5 – 30 °C
The value on the display appears as a temperature in °C
if the heating system is controlled by a room sensor. To
change the room temperature, increase or reduce the
value on the display.
1.
Browse to the function page.
2.
Press the screen with your finger.
3.
Select temperature:
4.
Save by pressing the green button.
Caution
A change in the room temperature can be
slowed down by the thermostats for the radiat-
ors or the underfloor heating. For this reason,
open the thermostat valves fully, except in
those rooms where a cooler temperature is
required, e.g. bedrooms.
TIP
Wait 24 hours before making a new setting,
so that the room temperature has time to sta-
bilise.
Displaying
• current indoor temperature if the indoor sensor or
wireless sensor/thermostat is connected to the relev-
ant climate system.
• required indoor temperature
• installed zones (Up to 10 can be displayed. Select the
zones that you want to display in menu 7.)
• controlling wireless temperature sensors and/or ther-
mostats
• status if you are currently operating prioritised cooling.
HOT WATER
In the event of a temporarily increased demand for hot
water, you can choose to increase the temperature of
the hot water in this menu.
This function is activated when you press More hot
water and switches off automatically when the temper-
ature reaches the set value.
Press Cancel to cancel the increase.
You can also select "More hot water" in the main
product’s menu 2.1.
Displaying
• hot water quantity
• status for "More hot water"
• status if you are currently operating prioritised hot
water.
35NIBE RMU S40 | GB