Menu 5 - SERVICE
OVERVIEW
5.1.1 - hot water settings *5.1 - operating settings5 - SERVICE
5.1.2 - max flow line temperature
5.1.3 - max diff flow line temp.
5.1.4 - alarm actions
5.1.12 - addition
5.1.14 - flow set. climate system
5.1.22 - heat pump testing
5.1.23 - compressor curve
5.2.2 - installed heat pump5.2 - system settings
5.2.4 - accessories
5.4 - soft in/outputs
5.5 - factory setting service
5.6 - forced control
5.7 - start guide
5.8 - quick start
5.9 - floor drying function
5.10 - change log
5.11.1.1 - heat pump5.11 - heat pump settings
5.11.1.2 - charge pump (GP12)
5.12 - country
* Accessory needed.
Go to the main menu and hold the Back button in for 7
seconds to access the Service menu.
Sub-menus
Menu SERVICE has orange text and is intended for the
advanced user. This menu has several sub-menus.
Status information for the relevant menu can be found
on the display to the right of the menus.
operating settings Operating settings for the control
module.
system settings System settings for the control mod-
ule, activating accessories etc.
soft in/outputs Setting software-controlled inputs and
outputs on terminal block (X2).
factory setting service Total reset of all settings (includ-
ing settings available to the user ) to default values.
forced control Forced control of the different compon-
ents in the indoor module.
start guide Manual start of the start guide which is run
the first time when the control module is started.
quick start Quick starting the compressor.
NOTE
Incorrect settings in the service menus can
damage the installation.
MENU 5.1 - OPERATING SETTINGS
Operating settings can be made for the control module
in the sub menus.
MENU 5.1.1 - HOT WATER SETTINGS
The hot water settings require that hot water production
is activated in menu 5.2.4 accessories.
NIBE SMO 20Chapter 8 | Control38