EN
English – 8
7.2.3 - Level two functions (adjustable parameters)
Imput Led Parameter Led (level) Value Description
L1 Low
L1 Motor force L2 Medium
L3 High
L1 Open - stop - close - open
L2
Step-by-step
L2 Open - stop - close - stop
Function
L3 Condominium operation
L1 15 seconds
L3 Pause Time L2 30 seconds
L3 60 seconds
Note – “
” represents the factory setting.
All the parameters can be adjusted as required without any contraindication; only the adjustment of the “motor force” could require special care:
• Do not use high force values to compensate for points of abnormal friction on the leaf. Excessive force can compromise the operation of the safety system
or damage the leaf.
• If the “motor force” control is used to assist the impact force reduction system, measure the force again after each adjustment in compliance with EN
standard 12445.
•Wearandweatherconditionsmayaffectthemovementofthegate,thereforeperiodicre-adjustmentsmaybenecessary.
TABLE 15 - Elenco funzioni programmabili: secondo livello
Adjust the sensibility of the motor force control to suit
the type of gate. The “High” adjustment is more suitable
for heavier and larger gates
Manages the sequence of controls associated to the
Step-by-Stepinputortothe1stradiocommand(see
tables4and5)
Adjusts the pause time, namely the time which lapses
before automatic closure. This will only have an effect if
automatic closing is active
7.2.4 - Level two functions (adjustable parameters)
The adjustable parameters are factory set as shown in table 15, with: “
“. However, they can be changed at any time as shown in Table 16. Follow the pro-
cedurecarefully,asthereisamaximumtimeof10secondsbetweenpressingonebuttonandanother.Ifalongerperiodoftimelapses,theprocedurewillnish
automaticallyandmemorizethemodicationsmadeuptothatstage.
TABLE 16 - Changing the adjustable parameters
01. Press the button [Set] andholditdown(approx.3s)
02. Release the [Set]buttonwhenL1LEDstartsashing
03. Press button [st] tomovetheashingLEDontotheinputLEDrepresentingtheparameterwhichistobechanged
04. Press the button [Set] and hold it down during step 5 and 6
05. Waitapprox.3seconds,afterwhichtheLEDrepresentingthecurrentleveloftheparameterwhichistobemodiedwilllightup
06. Press button [st] to move the LED representing the parameter value
07. Release the button [Set]
08. Wait10secondsbeforeleavingtheprogrammetoallowthemaximumtimetolapse
Note – Points 3 to 7 can be repeated during the same programming phase in order to set other parameters.
3 s
10 s
L1
SET
SET
SET
SET
SET
7.2.5 - Level one programming example (ON-OFF functions)
Thesequencetofollowinordertochangethefactorysettingsofthefunctionsforactivating“HighSpeed”(L2)and“AutomaticClosing”(L3)havebeenincluded
as examples.
TABLE 17 - Level one programming example
01. Press the button [Set] andholditdown(approx.3s)
02. Release the [Set]buttonwhenL1LEDstartsashing
03. Press the [st]buttononcetomovetheashingLEDtoLEDL2
04. Press the [Set] buttononcetochangethestateofthefunctionassociatedwithL2(MotorSpeed)
LEDL2willnowashwithlongashes
05. Press the [st]buttononcetomovetheashingLEDtoLEDL3
06. Press the [Set]buttononcetochangethestateofthefunctionassociatedwithL3(AutomaticClosing)
LEDL3willnowashwithlongashes
07. Wait10secondsbeforeleavingtheprogrammetoallowthemaximumtimetolapse
Once these operations have been completed, LEDs L2 and L3 must remain on to indicate that the “High Motor Speed” and “Automatic Closing” functions
are active
.
SET
SET
SET
SET
3 s
10 s
L1
L2
L3
L3
L2