Advance programming opons and their denions.
Barrier Speed
This opon allows you to reduce the maximum run speed in either both open and close direcon or
independently.
So stop speed
This opon allows you to adjust the speed the barrier slows down to when the so stop switches are
triggered.
Aux Relay Setup.
Lock mode - This opon allows you to control either a electro-mechanical lock like an electric rim lock or a
magnec lock. The relay on me can be adjusted in strike lock mode.
RX1 Module - This opon allows you to combine the third channel of the receiver with the auxiliary relay
to operate like an ET RX1 receiver. The relay can be set to latch mode or the on relay on me can be
adjusted to any me between 1 and 60 seconds. The receiver is a single shot receiver.
Light switch - This opon is used as a switch in the driveway lighng circuit where the lights will come on
as the barrier opens and will switch o aer the barrier has closed again. In this mode the third channel
of the receiver when triggered will switch the auxiliary relay no maer the barrier posion. There are two
on mes which are adjustable. Light on me whenever barrier opens and light on me when remotely
triggered.
Trac light - This opon allows for med trac light switching between green and red.
Blue-bus Setup.
This control unit can be used with the NICE Blue-bus two wire devices like the Blue-bus safety beam
products. This funcon must be run when adding or removing any Blue-bus devices to the system.
Power Sengs.
Baery charger - This opon allows you to disable the baery charger where a larger capacity intelligent
charger has been installed addionally to maintain the baery level of addional baeries larger than
7Ah. By disabling the built in charger you remove any possibility of interfering with the external charger’s
diagnoscs thus opmising the external baery and chargers performance.
AC monitoring - This opon allows you to disable the Vac mains failure monitoring on sites where a solar
panel system has been installed to maintain the baery.
Controller setup.
LCD Contrast Adj - This allows you to adjust the contrast between the text and the background of the LCD
display.
Adv Beam Setup - In the case of a safety beam circuit being installed without an end of line resistor,
it is sll possible to meet the stringent CE safety standards by acvang this funcon that intelligently
monitors the safety beam circuit.
Alarm output setup - The Drive and Wide series of operators, monitor for tampering condions namely;
safety beam tampering, barrier lied in all of the series and barrier kept open for too long in the case of
the Drive 500, 600, 1000 and Wide.
Jammed open - Use this feature to adjust the length of me the barrier is permied to remain open for
before the alarm acvates.
On board alarm - Use this feature to enable or disable the on board buzzer sounding whenever the
alarm acvates.
Alarm output invert - Use this feature to set the alarm output to switch to 0V (Disable) or switch from
0V (Enable) in an alarm condion.
BT on-board - Use this feature to enable or disable the on-board BT buon.
Wired BT Enable - Use this feature to enable or disable the hardwired BT input.
Wired E-Stop Enable - Use this feature to enable or disable the hardwired pedestrian input.
Wired Open only Enable - Use this feature to enable or disable the hardwired loop input.
PIN Code lock-out - Use this feature to prevent any access to the programming menus.
Cycle count - Use this to see how many mes the barrier has been operated. This counter cannot be reset
in the eld.
Event log - Use this to see a log of the most recent barrier open and close operaons.
Fault log - Use this to see a log of the last 30 fault condions.
Trigger log - Use this to see a log of the last 30 triggers.
Last overload info - Use this to see the recorded posion of the last barrier overload.
Firmware version - Use this to see the control card rmware version.
Hardware version - Use this to see the control card hardware version.
IEC Standards Use this feature to enable or disable IEC safety standards mode.
Reset and Restore
Set restore point - Use this to set a restore point.
Restore sengs - Use this feature to restore all controller sengs to the last saved restore point.
Clear logs - Use this feature to clear the event, fault and trigger logs. NB! this does not clear the cycle
counter.
Factory reset - Use this feature to default all controller sengs to factory sengs. NB! this does not
factory reset the receiver memory or clear the cycle counter.