4.17.1 Cable layout
Figure 4-35 shows the clearances which should be observed around the drive and related ‘noisy’ power cables by all sensitive control signals / equip-
ment.
Figure 4-35 Drive cable clearances
4.17.2 EMC requirements (first and second environments)
Operation in the first environment
An external EMC filter will always be required.
This is a product of the restricted distribution class according to IEC 61800-3
In a residential environment this product may cause radio interference in which case the user may be required to take adequate
measures.
Optional braking resistor and overload
Do not place sensitive
(unscreened) signal circuits
in a zone extending
300 mm (12”) all around the
Drive, motor cable, input
cable from EMC filter and
unshielded braking resistor
cable (if used)
300 mm
(12 in)
Elevator motor