Table 6-2 User Menu A Open loop, RFC-A and RFC-S parameters
Parameter
Range(Ú)Default(Ö)
Type
OL RFC-A RFC-S OL RFC-A RFC-S
A00 Parameter {A00} 0 to 65535
RW Num ND NC PT
A01 User Security Status {H02}
User Menu A (0), All Menus (1),
Read-only User Menu A (2), Read-only (3),
Status Only (4), No Access (5)
RW Txt ND PT
A02 Drive Control Mode {B01} Open loop (1), RFC-A (2), RFC-S (3)
Open loop
(1)
RFC-A (2) RFC-S (3) RW Txt ND NC PT
A03 Parameter Cloning {N01}
None (0), Read (1), Program (2),
Auto (3), Boot (4)
None (0) RW Txt NC US
A04 Total Output Current {J22}+
VM_DRIVE_CURRENT_UNIPOLAR A RO Num ND NC PT FI
A05 Percentage Load {J23}+
VM_USER_CURRENT % RO Num ND NC PT FI
A06
Profile Speed {J39} 0 to 10000 mm/s
RO Num ND NC PT
Actual Speed {J40}
0 to 10000 mm/s RO Num ND NC PT
A07 Output Power {J59}+
VM_POWER kW RO Num ND NC PT FI
A08 Output Frequency {J60} +VM_SPEED_FREQ_REF Hz
RO Num ND NC PT FI
A09 Output Voltage {J61}+
VM_AC_VOLTAGE V RO Num ND NC PT FI
A10 Control Input Mode {H11}
Analog Run Prmit (0), Analog 2 Dir (1),
Priority 1 Dir (2), Binary 1 Dir (3), Priority 2 Dir (4),
Binary 2 Dir (5), Control Word (6), DCP3 (7), DCP4 (8)
Priority 1 Dir (2) RW Txt US
A11 Direction Input Invert {H12} Off (0) or On (1) 0ff (0) RW Bit US
A12 Drive Encoder Type {C01}
AB (0), FD (1), FR (2),
AB Servo (3), FD Servo (4),
FR Servo (5), SC (6),
SC Hiperface (7), EnDat (8),
SC EnDat (9), SSI (10),
SC SSI (11), SC Servo (12),
SC SC (15)
AB (0)
AB Servo
(3)
RW Txt US
A13
Drive Encoder Auto
Configuration Select
{C02}
Disabled (0) or Enabled (1) Enabled (1) RW Txt US
A14
Drive Encoder Rotary
Pulses Per Revolution
{C03}
1 to 100,000 ppr 1024 ppr 4096 ppr RW Num US
A15
Drive Encoder Voltage
Select
{C04}
5 V (0), 8 V (1), 15 V (2) 5V (0) RW Txt US
A16
Position Feedback
Phase Angle
{C13}
0.0 to 359.9 ° 0.0 °
RW Num ND US
Slip Compensation
Enable
{B10} Off (0) or On (1)
On (1) RW Bit US
A17
Drive Encoder Feedback
Reverse
{C12}
Off (0) or On (1) Off (0) RW Bit US
Low Frequency Voltage
Boost
{B12} 0.0 to 25.0 %
3.0 % RW Num US
A18 Motor Rated Current {B02}+
VM_RATED_CURRENT A Maximum Heavy Duty Rating (J05) RW Num RA US
A19 Motor Rated Voltage {B03}+
VM_AC_VOLTAGE_SET V
200 V drive: 230 V
50 Hz - 400 V drive: 400 V
60 Hz - 400 V drive: 460 V
575 V drive: 575 V
690 V drive: 690 V
RW Num RA US
A20 Number Of Motor Poles {B05} Automatic (0) to 480 Poles (240) Automatic (0) 16 Poles (3) RW Txt US
A21 Motor Rated Frequency {B06} 0.0 to 550.0 Hz
50 Hz: 50.0
60 Hz: 60.0
RW Num US
A22 Motor Rated Speed {B07} 0 to 33000 rpm
50 Hz:
1500.0
rpm,
60 Hz:
1800.0 rpm
3000.00
rpm
3000.00
rpm
RW Num US
A23
Open Loop Control
Mode
{B09}
Ur S (0), Ur (1),
Fixed (2),
Ur Auto (3),
Ur I (4)
Ur I (4) RW Txt US
RFC: Action On Enable
{B09}
Disabled (0),
Short (1),
Short Once (2),
Long (3),
Long Once (4)
Disabled (0) RW Txt US